AI data centers

The floor, the power, the cooling — and everything on it.

AI hardware has moved faster than the buildings meant to hold it. A single modern cabinet can draw what a street of houses draws, and it will throttle or trip within seconds of losing flow. We design for that reality, manage the build, commission it, run it with AIDA ECOS — and we supply the equipment that makes it live.

Utility serviceGenerationUPS · storage SwitchgearBusway · taps Air‑cooled hallcontainment · CRAH Liquid‑cooled hallmanifolds · in‑rack CDU Network & storage Chillers · heat rejectionPumps · facility CDUs Loop chemistryLeak detectionCameras · access AIDA ECOS — one operating picture, verified continuously

Four things, not one.

Most providers hand off at a boundary. We carry the design intent across all four, which is why the thing that gets built is the thing that was drawn.

Design

Lead architecture

Facility design intent as an AI system — power, cooling, network, monitoring and operations coordinated into one validated design, with the OEM specifications and the engineer of record reconciled rather than assumed.

Build

Program and site management

Integrated schedule, risk register, change control and day‑to‑day site direction alongside the contractor of record — sequencing, quality and readiness, with inspection and acceptance on the owner's behalf.

Operate

Commission and run

Commissioning through integrated systems test, then steady‑state operation on {AIDA}: redundancy verified continuously, efficiency reported to billing standard, incidents escalated on a defined path.

Supply

We sell it too

Racks, power distribution, UPS and storage, chillers and CDUs, switchgear, structured cabling, network, cameras and access control — procured, delivered and installed. See the categories →

utilitygenerationUPS chiller plantheat rejection every cabinet metered — power, thermal, flow and leak, one second at a time data hall

Telemetry, one second at a time.

From the utility service to the cabinet manifold, every meaningful point is read, checked against its design envelope and recorded. That is what turns a Tier III claim into a Tier III demonstration — and what makes a billing‑grade efficiency figure defensible when a tenant asks how it was derived.

  • Power path monitored from the service entrance through switchgear, UPS and busway to each metered tap‑off
  • Thermal and airflow per cabinet in the air halls; flow, differential pressure and supply/return per cabinet in the liquid halls
  • Redundancy verified continuously rather than assumed between maintenance windows
  • Leak zones, chemistry and make‑up water tracked as a single water story, not three separate reports

The engineering, subject by subject.

Power behaves differently under AI load.

Synchronised training jobs swing facility demand in milliseconds. Utility service, generation, UPS topology and distribution all have to be engineered for that profile — and then verified continuously, because a design that was right on paper drifts in service.

  • Utility capacity, service agreements and energisation sequencing — the real gate on any aggressive schedule
  • Step‑load and transient management, including energy storage and power smoothing at rack or facility level
  • Generation sizing, fuel logistics and air permitting; behind‑the‑meter and bridge power options where the utility timeline will not cooperate
  • UPS topology decided explicitly — and cooling always protected, because liquid‑cooled compute trips on thermal in seconds
  • High‑amperage busway and metered tap‑offs matched to the OEM power shelves, not to a generic assumption
  • Harmonics and power quality: K‑rated transformers and filtering sized for the actual load profile
AIR‑COOLED CABINETSDIRECT‑LIQUID CABINETS inlet · airflow · containment flow · ΔP · supply / return · leak every cabinet metered — power, thermal and fluid, at the demarcation

We do not just specify it. We supply it.

This is the part that surprises people: we execute the work, design the solution and support it after implementation — and we also sell the products and services that bring the facility to live status. One accountable party from drawing to energisation.

Power equipment

Utility to cabinet

Switchgear and transformers, UPS and lithium‑ion storage, energy storage for transient smoothing, generation, busway and metered rack power distribution.

Cooling & water

Plant to manifold

Chillers and heat rejection, facility CDUs, pumps and hydronics, containment and rear‑door heat exchangers, coolant chemistry programmes and leak detection.

Compute & racks

Cabinets and the systems in them

Accelerated compute platforms, cabinets, cages and secure staging, and the in‑rack distribution that feeds them.

Network

Fabric and carriers

Structured cabling and trunks, management‑plane switching, meet‑me room build and carrier coordination.

Security systems

Cameras and access

Video management, camera estate, access control, fire detection and suppression coordination.

Services

The people, too

Commissioning agents, water treatment programmes, structural and floor‑loading assessment, environmental and air permitting support, and 24/7 remote hands.

We stay vendor‑independent. We hold preferred and alternate selections in every category, chosen for open telemetry, lead‑time realism and regional support — and we will recommend the option that serves the owner, including one we do not supply. Indicative pricing is presented as advisory ranges from the tenant's perspective until the design decisions are actually made.

SAP · Workday · Oracle · Salesforce AIDA ECOS intelligence layer Power · Cooling · Compute · Network

AIDA ECOS on the floor.

A facility is judged on evidence: that it is concurrently maintainable, that efficiency is measured the way the contract says, that an incident was detected and escalated. ECOS produces that evidence continuously instead of assembling it before an audit.

  • Per‑rack power, inlet temperature, airflow and pressure with alarms tied to the service envelope
  • Per‑rack coolant flow, differential pressure and supply/return temperature at the demarcation, with leak detection integrated
  • Continuous verification that generators, UPS, pumps and cooling redundancy are genuinely available
  • Revenue‑grade metering with automated efficiency calculation and auditable tenant reporting
  • Predictive maintenance on rotating and electrical plant, with work orders raised before failure
  • Work‑order, asset and access tracking for remote‑hands operations, with a tenant portal

Tell us what has to work.

An ERP programme with a date that cannot move. A facility that has to energise on schedule. An estate that needs to run itself more accurately than it does today. Start there — we will tell you honestly what it takes.